Shouli compressor parts special oil use specifications and operating procedures

Sullair Compressor Parts Special Oil Usage Specification and Operation Process Regardless of whether the user is using an oil-free or oil-injector, whether the user uses an air-cooled Sullair compressor accessory oil or a water-cooled Sullair compressor accessory Oil, must solve the problem of ventilation of air compressors. According to our past experience, more than 50% of the faults in Shouli Compressor Parts' special oils are due to neglect or misunderstanding in this respect. When the air is compressed, a large amount of heat will be emitted. If the heat cannot be discharged into the air compressor room in time, the room temperature of the air compressor room will gradually increase, so that the temperature of the special oil suction port of the Sullair compressor parts is It will become higher and higher. Such a vicious cycle will cause the exhaust gas temperature of the Shouli compressor parts to be high and alarm, and because the density of the high-temperature air is small, the gas production will be reduced. For the special oil for water-cooled Sullair compressor parts, most of the heat is transferred to the cooling water through the heat exchanger, and the heat is taken away by the cooling water. At this time, only a small ventilation fan is required to send the main motor. A small amount of heat is taken away. For air-cooled Sullair compressor parts, it is necessary to have a large amount of fresh air to exchange the heat generated by the compression process. Then the fresh air inlet must be considered. It is good to be close to the special oil cooling air inlet of the Sullair Compressor Parts (the air inlet for the compression part is also preferably close to the fresh air inlet). If necessary, a separate air duct can be provided to introduce fresh air. This can avoid the hot air in the air compressor room from affecting the cooling process, depending on the construction of the air compressor room and the customer's situation. Generally, it is necessary to set the air duct to export the hot air that has been exchanged by heat to the air compressor room, and if necessary, set a fan or fan at the outlet to enhance the export effect of the hot air. The fresh air inlet mentioned above needs to be set at the low position of the air compressor room, and the hot air outlet (including the corresponding fan or fan) should be set at a high position. Because the density of the hot air is small, it will generally stay at a high position. Conducive to the export of hot air, and at the same time prevent the discharged hot air from entering the air inlet again and short circuit of the air flow. It should be noted that it is preferable to arrange the fresh air inlet and the hot air outlet on the opposite walls, respectively, for the purpose of preventing the discharged hot air from entering the air inlet again and causing a short circuit of the air flow. It is better to install a dust-proof grid at the entrance of the fresh air to avoid more dust or catkins and other debris entering the air compressor room. It is better to provide a rain cover at the air outlet of the hot air to prevent rainwater from flowing into the exhaust air duct. Regardless of the air duct of the air inlet or the air duct of the air outlet, relatively large diameter reduction or elbow should be avoided, because this will cause relatively large ventilation resistance and affect the ventilation effect. Because the air in the air compressor room is continuously used for compression and cooling, and the fresh air supplement is generally passive, the air pressure room generally maintains a certain negative pressure, which is normal. However, if the negative pressure value exceeds the allowable value, it means that the size of the air inlet or the amount of air intake needs to be improved, because the negative pressure value is too large, resulting in poor cooling effect and reduced exhaust gas volume. Although the above content is relatively simple, it is very important. If you can work with the user to do a good job in this area, you have already ruled out the possibility of 50% failure. It can be seen that more energy is spent on us and users. It is very worthwhile. 1. The air compressor operating environment should be kept clean and dry. The gas storage tank shall be placed in a well ventilated place and shall not be welded or hot worked within a radius of 15 m. 2. The gas storage tank and gas pipeline should be tested for water pressure every two years. The pressure gauge and safety valve should be verified at least once a year. 3. The starting air compressor must be carried out under no-load condition. After the operation is normal, it will gradually enter the load operation. 4. Before opening the air supply valve, the gas pipeline should be connected well, the gas pipeline should be kept clear, and the gas should not be distorted and notified to the relevant personnel before it can be delivered. No one is allowed to work or stand before the air outlet. The gas storage tank should be placed in a ventilated place, and it is strictly prohibited to expose to sunlight and high temperature. 5. The maximum pressure in the gas tank cannot exceed the nameplate, and the safety valve should be sensitive and effective. 6. The inlet and outlet valves, bearings and components should be free of abnormal noise or overheating. 7. When one of the following conditions is found, stop the inspection immediately and find out the cause before the fault can be solved before the operation: water leakage, air leakage, leakage or sudden interruption of cooling water; the indication values ​​of pressure gauge, thermometer and ammeter exceed the regulations; The gas pressure suddenly rises, the exhaust valve and the safety valve fail; the machine has abnormal noise or the motor brush has a strong spark. 8. If the cylinder is overheated due to lack of water during operation, the cold water cannot be added immediately. The cylinder body must be naturally cooled to below 60 °C to add water. 9. The installation of special oil power cords for electric life compressor parts must meet the requirements of safe electricity specifications. Repeated grounding is reliable, and the electric shock protector is sensitive. In case of power failure during operation, the power should be cut off immediately and restarted after the call. 10. When stopping, first remove the load, then separate the main clutch; then stop the internal combustion engine or motor. 11. After the special oil of Sullair Compressor Parts is shut down, close the cooling water valve, open the bleed valve, and release the oil and water in the coolers and air tanks at all levels. When the temperature is lower than 5 °C, the water in each part should be drained before leaving. 12. When purging parts with compressed air, do not aim the tuyere at the human body or other equipment. 13. After the work is completed, the remaining gas in the gas tank is released. Shouli compressor parts special oil should be cooled off in winter.

Shanghai Longzhi Electromechanical Equipment Co., Ltd. specializes in various types of compressor parts, including Atlas compressor parts, Ingersoll Rand compressor parts, Sullair compressor parts, Fusheng compressor parts, CompAir Compressor parts, etc., at the same time to undertake the maintenance and maintenance of various brands of compressors, to provide users with comprehensive after-sales service. Service Hotline Mr. Wang

SMC Manhole Cover

Fiberglass SMC manhole cover are mainly used for 1, Electric power pipeline well; Post, telecommunication, communication pipeline well;

2, Street lamp well; Fire control well; All kinds of valve well;

3, City water, drainage pipeline well; Heat supplied, gas well;

4, Anti-corrosion project, option ditch; It can be made according to customers requirements.

SMC Manhole Cover

Shandong Hiking International Commerce Group Co.,Ltd , https://www.constructionfrp.com